SPECIFICATION
|
Phase |
Single Phase |
|
Form Factor |
Rackmount, Tower |
|
UPS Topology |
Online Double Conversion |
|
Energy Saving Technology |
ECO Mode Efficiency > 95% |
|
Active PFC Compatibility |
Yes |
|
Input |
|
|
Generator Compatibility |
Yes |
|
Nominal Input Voltage (Vac) |
230 ± 10% |
|
Input Voltage Range (Vac) |
190 ~ 300 |
|
Adjustable Voltage Range (Vac) |
80 |
|
Input Frequency (Hz) |
50 ± 10 / 60 ± 10 |
|
Input Frequency Detection |
Auto-sensing |
|
Rated Input Current (A) |
9 |
|
Input Power Factor |
0.99 |
|
Input Connector Type |
IEC C14 |
|
Detachable Power Cord Plug Type |
Schuko x 1 |
|
Power Cord Length (ft) |
5 |
|
Power Cord Length (m) |
1.5 |
|
Output |
|
|
Capacity (VA) |
2000 |
|
Capacity (Watts) |
1800 |
|
On Battery Waveform |
Pure Sine Wave |
|
On Battery Voltage(s) (Vac) |
208 / 220 / 230 / 240 ± 1% (Configurable) |
|
On Battery Frequency (Hz) |
50 ± 0.5% / 60 ± 0.5% (Configurable) |
|
Power Factor |
0.9 |
|
ECO Mode Voltage Tolerance |
± 15% |
|
Overload Protection |
Internal Current Limiting, Circuit Breaker, Fuse |
|
Overload Protection (Line Mode) |
110–120% Load for 1 min, >120% Load Immediately |
|
Overload Protection (Battery Mode) |
110–120% Load for 10 sec, >120% Load Immediately |
|
Overload Protection (Bypass Mode) |
>130% Load Immediately |
|
Crest Factor |
3:1 |
|
Harmonic Distortion (Linear Load) |
THD < 3% |
|
Harmonic Distortion (Non-linear Load) |
THD < 5% |
|
Internal Bypass |
Automatic Bypass, Manual Bypass |
|
Outlet(s) - Total |
8 |
|
Outlet Type |
IEC C13 x 8 |
|
Battery & Surge Protected Outlets |
8 |
|
Critical Load (CL) Outlets |
4 |
|
Non-critical Load (NCL) Outlets |
4 |
|
Typical Transfer Time (ms) |
0 |
|
Battery |
|
|
Runtime at Half Load (min) |
13.1 |
|
Runtime at Full Load (min) |
3.8 |
|
Typical Recharge Time (Hours) |
4 |
|
Maximum Charging Current (A) |
1.5 |
|
Start On Battery |
Yes |
|
Smart Battery Management (SBM) |
Yes |
|
User-replaceable |
Yes |
|
Hot-swappable |
Yes – Qualified Personnel Only |
|
Battery Type |
Sealed Lead-acid |
|
Replacement Battery Pack (RBP) |
RBP0157 |
|
RBP Quantity |
1 |
|
Battery Quantity per RBP |
4 |
|
Battery Voltage per RBP (V) |
48 |
|
Compatible Extended Battery Module (EBM) |
BPSE48V40ART2U |
|
Extended Battery Module Auto-detection |
Yes |
|
Max. EBM Quantity |
3 |
|
Surge Protection & Filtering |
|
|
Surge Suppression (Joules) |
363 |
|
EMI/RFI Filtration |
Yes |
|
Phone/Network Protection |
RJ11/RJ45 (1-in, 1-out Combo) |
|
Management & Communications |
|
|
LCD Panel |
Yes |
|
LCD Type |
Color LCD |
|
LCD Orientation |
Rotatable LCD – Manual |
|
LCD Display |
Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Event & Log |
|
LCD Settings & Control |
Mode Setting, Alarm Setting, Input & Output, Battery Setting |
|
HID Compliant USB Port(s) |
1 |
|
Dry Contact (with Relay) |
Yes |
|
Emergency Power Off (EPO) Port |
Yes |
|
Audible Alarms |
Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery |
|
Management Cable(s) |
Power Cord x2, USB Cable x1 |
|
Power Management Software |
PowerPanel Business (Recommended) |
|
SNMP/HTTP Remote Monitoring |
Yes – with optional RMCARD205 |
|
Physical |
|
|
Enclosure Construction |
Metal |
|
Color |
Black |
|
Rackmount Rail |
Yes |
|
Rackmount Ears |
Yes |
|
Dimensions (WxHxD) (in) |
17.24 x 3.46 x 16.93 |
|
Dimensions (WxHxD) (mm) |
438 x 88 x 430 |
|
Weight (lbs) |
42.3 |
|
Weight (kg) |
19.2 |
|
Installed Rack Height (U) |
2 |
|
Shipping Dimensions |
|
|
Shipping (WxHxD) (in) |
21.3 x 9 x 21.7 |
|
Shipping (WxHxD) (mm) |