EATON 9PX 1000i RT2U Uninterruptible Power Supply
Read our FAQs before ordering
Need Help / Out of Stock? Chat with us.
SPECIFICATION
|
Models (VA Rating) |
1000VA |
|
Rating (VA/W) |
1000VA/1000W |
|
Format |
RT2U (tower/rack 2U); 2200 & 3000VA also available in RT3U (tower/rack 3U) |
|
Technology |
On-line double conversion with Power Factor Correction (PFC) system |
|
Nominal Voltage |
200/208/220/230/240V |
|
Input Voltage Range |
176–276V without derating (up to 100–276V with derating) |
|
Input Frequency Range |
40–70Hz, 50/60Hz auto-selection, frequency converter mode |
|
Efficiency (1000VA) |
Up to 91.5% (online mode), up to 97.5% (Hi-efficiency mode) |
|
Efficiency (1500VA) |
Up to 92.5% (online mode), up to 97.5% (Hi-efficiency mode) |
|
Efficiency (2200VA) |
Up to 93.5% (online mode), up to 98% (Hi-efficiency mode) |
|
Efficiency (3000VA) |
Up to 94% (online mode), up to 98% (Hi-efficiency mode) |
|
Input Connections |
1000VA: 1 IEC C14 (10A); 1500–3000VA: 1 IEC C20 (16A) or terminal block (HotSwap MBP HW) |
|
Output Connections |
8 × IEC C13 (10A); 1500–3000VA: 8 × IEC C13 + 2 × IEC C19 (16A) |
|
HotSwap Outputs |
4 FR/Schuko or 3 BS or 6 IEC 10A sockets or terminal blocks (HW version) |
|
Switched Outlet Groups |
2 outlet groups |
|
Battery Management |
ABM® technology, temperature-compensated charging, automatic battery test, deep discharge protection, auto detection of external battery modules |
|
Backup Time Loads |
300W, 500W, 800W, 1200W, 1800W, 2500W |
|
Typical Backup (1000VA) |
28 / 16 / 9 mins |
|
1000VA + EBM |
134/530, 79/316, 47/188 mins |
|
Typical Backup (1500VA) |
38 / 23 / 13 / 7 mins |
|
1500VA + EBM |
143/536, 86/319, 52/192, 32/120 mins |
|
Typical Backup (2200VA) |
43 / 25 / 15 / 9 / 5 mins |
|
2200VA + EBM |
206/818, 123/491, 74/297, 47/189, 29/118 mins |
|
Typical Backup (3000VA) |
60 / 36 / 22 / 13 / 7 / 4 mins |
|
3000VA + EBM |
221/824, 135/504, 83/307, 52/194, 33/122, 22/82 mins |
|
Communication Ports |
USB + RS232 + remote ON/OFF + remote power off + output relay |
|
Communication Slot |
1 slot for Network-M2, INDGW-M2, or Relay-MS cards |
|
Operating Temperature |
0°C to 40°C |
|
Noise Level |
35dB (1000VA), 40dB (others) |
|
Safety Standards |
IEC/EN 62040-1, UL 1778, CSA 22.2 |
|
EMC Standards |
IEC/EN 62040-2, FCC Class B, CISPR22 Class B |
|
Certifications |
CE, CB (TUV), cULus, EAC, RCM, KC, Energy Star |
|
UPS Dimensions (1000VA) |
86.5 × 440 × 450 mm / 17.4 kg |
|
UPS Dimensions (1500VA) |
86.5 × 440 × 450 mm / 18.9 kg |
|
UPS Dimensions (2200VA) |
2U: 86.5 × 440 × 605 mm / 25 kg; 3U: 130 × 440 × 485 mm / 24.5 kg |
|
UPS Dimensions (3000VA) |
2U: 86.5 × 440 × 605 mm / 27.6 kg; 3U: 130 × 440 × 485 mm / 27.4 kg |
|
EBM Dimensions (1000VA) |
86.5 × 440 × 450 mm / 29.8 kg |
|
EBM Dimensions (2200/3000VA) |
2U: 86.5 × 440 × 605 mm / 39.2 kg; 3U: 130 × 440 × 485 mm / 38.2 kg |